Rotary
Torque & Angle Transducer
Rotary
transducers are designed to measure the torque and angle
from continuously rotating shafts such as non impulse power tools.
These
transducers are known as 'SMART' transducers. They have built in
intelligence in the form of a memory circuit which contains essential
information about the transducer which can be read by the appropriate
type of instrument (Pro Log), thus reducing set up time.
They
will also work with instruments that cannot read the memory information,
by inputting the relevant calibration details manually.
|

•
Accuracy of ± 0.5%
of reading, through out the calibrated range.
•
Wide calibration range means that the minimum number of transducers are
required.
|
Rotary
Torque & Angle Transducers- Imperial Calibration
|
Range
|
Part Number
|
A (mm)
|
B (mm)
|
C (mm)
|
D (mm)
|
E (mm)
|
Sq. Drive
|
Pulses / Degree*
|
Max RPM
|
|
5-100 Lbf In
|
50562.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4
|
1
|
5000
|
|
5-100 Lbf In
|
50567.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4 Hex
|
1
|
5000
|
|
50-1000 Lbf In
|
50563.xxx
|
83
|
56
|
70
|
83
|
46
|
3/8
|
2
|
2500
|
|
50-1000 Lbf In
|
50564.xxx
|
83
|
56
|
70
|
83
|
46
|
1/2
|
2
|
2500
|
|
0.5-10 Lbf Ft
|
50556.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4
|
1
|
5000
|
|
0.5-10 Lbf Ft
|
50566.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4 Hex
|
1
|
5000
|
|
3.75-75 Lbf Ft
|
50557.xxx
|
83
|
56
|
70
|
83
|
46
|
3/8
|
2
|
2500
|
|
5-100 Lbf Ft
|
50558.xxx
|
83
|
56
|
70
|
83
|
46
|
1/2
|
2
|
2500
|
|
7.5-150 Lbf Ft
|
50559.xxx
|
83
|
56
|
70
|
83
|
46
|
1/2
|
2
|
2500
|
|
25-500 Lbf Ft
|
50560.xxx
|
133
|
76
|
96
|
109
|
67
|
3/4
|
3
|
1500
|
|
50-1000 Lbf Ft
|
50561.xxx
|
133
|
76
|
96
|
109
|
67
|
1
|
3
|
1500
|
* Only when angle option specified.
Impulse
Rotary Torque & Angle Transducer
The
impulse Rotary differs from the Standard Rotary in that it has been
specifically designed to withstand,
and accurately measure the
torque and angle output from impulse power tools and certain non-impulse
tools with a severe clutch action.
Not
for use with impact tools.

Impulse
Rotary Torque & Angle Transducers- Imperial Calibration
|
Range
|
Part
Number
|
A
(mm)
|
B
(mm)
|
C
(mm)
|
D
(mm)
|
E
(mm)
|
Sq.
Drive
|
Pulses
/ Degree*
|
Max
RPM
|
|
5-100
Lbf In
|
50580.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4
|
1
|
5000
|
|
5-100
Lbf In
|
50585.xxx
|
67.
|
52
|
58
|
71
|
32
|
1/4
Hex
|
1
|
5000
|
|
50-1000
Lbf In
|
50581.xxx
|
83
|
56
|
70
|
83
|
46
|
3/8
|
2
|
2500
|
|
50-1000
Lbf In
|
50582.xxx
|
83
|
56
|
70
|
83
|
46
|
1/2
|
2
|
2500
|
|
0.5-10
Lbf Ft
|
50574.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4
|
1
|
5000
|
|
0.5-10
Lbf Ft
|
50584.xxx
|
67.5
|
52
|
58
|
71
|
32
|
1/4
Hex
|
1
|
5000
|
|
3.75-75
Lbf Ft
|
50575.xxx
|
83
|
56
|
70
|
83
|
46
|
3/8
|
2
|
2500
|
|
5-100
Lbf Ft
|
50576.xxx
|
83
|
56
|
70
|
83
|
46
|
1/2
|
2
|
2500
|
|
7.5-150
Lbf Ft
|
50577.xxx
|
83
|
56
|
70
|
83
|
46
|
1/2
|
2
|
2500
|
|
25-500
Lbf Ft
|
50578.xxx
|
133
|
76
|
96
|
109
|
67
|
3/4
|
3
|
1500
|
|
50-1000
Lbf Ft
|
50579.xxx
|
133
|
76
|
96
|
109
|
67
|
1
|
3
|
1500
|
*
Only when angle option specified.
Part Number Suffix System
|
Suffix
|
Meaning
|
|
.AMP
|
Supplied with an Amplifier.
|
|
.DTS
|
Supplied with a DTS instrument.
|
|
.IND
|
Calibrated mV/V.
|
|
.INDA
|
Calibrated mV/V with Angle.
|
|
.LOG
|
Calibrated with a pro-log in torque units.
|
|
.LOGA
|
Calibrated with a pro-log in torque units with
angle.
|
|